
Labor Reports
Verify
Retatrutide_RE10-0126: https://verify.janoshik.com/tests/97775-Retatrutide_10mg_QRV6U3J4V683
MOTS-c_MO20-0126: https://verify.janoshik.com/tests/97777-MOTSc_20mg_Q4K6XVEMLD5T
GHK-CU_HK100-0126: https://verify.janoshik.com/tests/97779-GHKCu_100mg_WXZ2GPR45KUR
Melanotan2_MT10-0126: https://verify.janoshik.com/tests/97778-Melanotan_II_10mg_H93WVPK7T3HP
BPC-157 BP10-0126: https://verify.janoshik.com/tests/97776-BPC157_10mg_VI4DU3VSE8JS
CJC-1295 + Ipamorelin Blend 10/10mg CJI10-0126:
https://verify.janoshik.com/tests/113717-CJC_DACIpamorelin_blend_SICFWDRHTSNS
Tirzepatide TZ10-0126: https://verify.janoshik.com/tests/113710-Tirzepatide_ZV12XTQXMNQD
SLU-PP-332 SLU1000-0126: https://verify.janoshik.com/tests/113720-SLUPP332_Z6WRY8VW5RL3
NAD+ NAD500-0126: https://verify.janoshik.com/tests/113712-NAD_PVB6XDFUICKS
Semax SE10-0126: https://verify.janoshik.com/tests/113713-Semax_8P9XPWTXSQHW
Selank SL10-0126: https://verify.janoshik.com/tests/113714-Selank_5P9DV3SYX8RL
TB-500 TB10-0126: https://verify.janoshik.com/tests/113715-TB500_SFWNN7ZU9TXW
KPV KPV10-0126: https://verify.janoshik.com/tests/113716-KPV_RUWZQAPA9491
Tesamorelin TE10-0126: https://verify.janoshik.com/tests/113718-Tesamorelin_1JXFVMEZ5PLN
Elamipretide (SS-31) SS10-0126: https://verify.janoshik.com/tests/113719-Elamipretide_SS31_EUXZ192BS6YS
Epitalon EP10-0126: https://verify.janoshik.com/tests/113711-Epithalon_IJLWIULS9NCS
Transparency Through Independent Verification
At BIONIX Research, we believe that trust is earned through transparency. Every batch of research compounds undergoes rigorous third-party laboratory testing before it reaches our members.
We partner with Janoshik — Europe's leading independent analytical laboratory specializing in peptide and research compound analysis — to provide unbiased verification of product identity, purity, and quality.
This page explains how to read and understand your Certificate of Analysis (COA), and what the analytical data means for your research.

What is Third-Party Testing?
Third-party testing means that an independent laboratory — with no financial interest in the sale of products — analyzes compounds to verify their contents.
Why this matters:
- ✅ Unbiased results: The lab has no incentive to pass or fail batches
- ✅ Scientific verification: Advanced analytical methods confirm identity and purity
- ✅ Quality assurance: Detects contaminants, impurities, or mislabeled products
- ✅ Research integrity: Ensures you're working with compounds that match specifications
Our testing partner: Janoshik operates state-of-the-art analytical facilities and is widely recognized in the research community for accurate, reliable testing.

Understanding Your Certificate of Analysis (COA)
A Certificate of Analysis (COA) is an official document from the testing laboratory that provides verified information about a specific product batch.
What's Included in a Janoshik COA:
| Section | What It Tells You |
|---|---|
| Product Information | Compound name, batch number, molecular formula |
| Quantity | Milligrams (mg) contained in the vial |
| Purity % | Consolidated purity result derived from HPLC and MS analysis |
| Testing Date | When the analysis was performed |
| Laboratory Details | Name, accreditation, contact information |
| Authorized Signature | QA approval from the testing facility |
How to Read Your COA:
- Check the batch number — Ensure it matches your product packaging
- Review quantity — Confirms milligram content matches your order
- Verify purity % — Look for ≥99% (represents combined analytical verification)
- Confirm date — Testing should be recent (within 12 months)
Analytical Methods: How Purity is Determined
Janoshik uses two complementary analytical techniques to verify your compound. The purity percentage shown on your COA represents the synthesized result of both methods — presented as a single, consolidated value for clarity.
HPLC (High-Performance Liquid Chromatography)
What it measures: Quantitative purity — the percentage of your target compound versus impurities.
How it works:
- The sample is dissolved and injected into the HPLC system
- Compounds separate as they flow through a specialized column
- A UV detector identifies each component as it exits
- Software calculates the area under each peak
The output: A chromatogram showing relative quantities of the target peptide versus any synthesis byproducts, degradation compounds, or contaminants.
Why it matters: HPLC identifies how much of the sample is your target compound versus other substances.
MS (Mass Spectrometry)
What it measures: Molecular identity confirmation — verifying the compound is chemically what it claims to be.
How it works:
- The sample is ionized and vaporized
- Ions are separated by mass-to-charge ratio in an electromagnetic field
- The detector creates a mass spectrum
- Results are compared against theoretical molecular weight
The output: A mass spectrum confirming the exact molecular weight of the peptide.
Why it matters: MS confirms you have the correct molecule — not a different peptide with similar properties or a completely misidentified compound.
How the Purity % is Calculated
The process behind your certificate:
- MS First — Confirms molecular identity "This IS the correct peptide"
- HPLC Second — Measures quantitative purity "This sample is X% pure target compound"
- Consolidated Reporting — Janoshik presents the final purity % as a synthesized value representing both analytical confirmations
What the % means:
- The purity percentage reflects the HPLC-measured quantity of correctly identified compound
- The MS verification ensures that the "pure" material is actually the intended peptide
- Together, they guarantee both identity and quality
Example:
- MS confirms: Molecular weight matches theoretical (correct identity)
- HPLC confirms: 99.1% of sample is this compound (quantitative purity)
- COA displays: Purity: 99.1%

Why Two Methods Are Essential
Using only one method creates verification gaps:
| If Only HPLC | If Only MS |
|---|---|
| Measures quantity but cannot confirm what molecule it is | Confirms identity but cannot measure how much is present |
| Could pass a different peptide with similar retention time | Could confirm correct molecule but miss 30% contamination |
The Janoshik approach: Both MS and HPLC are performed. The purity % represents the HPLC quantitative result only after MS has confirmed correct identity.
How to Verify Your Batch
Step 1: Locate Your Batch Number
Find the batch number printed on your product label or packaging (format: BNX-XXXX-XXXX).
Step 2: Access the Verification Portal
Visit our Verify Your Product page and enter your batch number.
Step 3: Review Your COA
Download the complete Certificate of Analysis showing:
- Quantity verification (mg)
- Purity % (consolidated HPLC + MS result)
Step 4: Cross-Reference with Janoshik
For additional verification, you can:
- Visit janoshik.com
- Search for BIONIX Research in their client database
- Contact Janoshik directly with your batch number
Frequently Asked Questions
Q: Does the COA show separate HPLC and MS results? A: Janoshik COAs present a consolidated purity percentage that represents the HPLC quantitative analysis performed after MS identity confirmation. This streamlined format displays the final synthesized result rather than raw chromatogram data.
Q: What does the purity % actually represent? A: The percentage reflects the proportion of correctly identified target compound (measured by HPLC) after molecular identity has been confirmed (verified by MS). It's a consolidated quality metric.
Q: How do I know both tests were performed? A: Janoshik's standard operating procedure for peptide analysis includes both MS (identity) and HPLC (quantification). A purity % without identity confirmation would not be issued.
Q: Why not show the full chromatograms? A: The consolidated format provides the essential quality metric (purity %) while maintaining certificate clarity. Full analytical data is available from Janoshik upon request using your batch number.
Q: How recent should the testing be? A: Ideally within 12 months. Lyophilized peptides are stable for 2-3 years when properly stored, but recent testing ensures batch integrity.
Our Quality Commitment
Every BIONIX Research compound is:
✅ Synthesized under GMP-compliant conditions
✅ Analyzed by independent third-party laboratory (Janoshik)
✅ Identity-verified via Mass Spectrometry
✅ Purity-quantified via HPLC (≥99%)
✅ Consolidated purity certification on COA
✅ Batch-tracked with unique identification
✅ Stored under optimal conditions until shipment
Research requires precision. Our dual-method verification ensures you can trust your materials.















